Development and Validation of RP-HPLC Method for Simultaneous Estimation of Aspirin and Rivaroxaban in Synthetic Mixture
Nazira Sarkis1*, Yaser Bitar2, Mohamad Medhat Sarraj3
1Department of Analytical and Food Chemistry, Faculty of Pharmacy, University of Aleppo, Syria.
2Department of Pharmaceutical Chemistry and Quality Control, Faculty of Pharmacy, University of Aleppo, Syria.
*Corresponding Author E-mail: nazirasarkis@gmail.com, medhatsarraj@gmail.com
ABSTRACT:
A Simple, sensitive, rapid, precise and accurate RP-HPLC method has been developed and validated for simultaneous estimation Aspirin and Rivaroxaban in synthetic mixture. The separation process was developed under optimized chromatographic conditions using a reversed phase of C18 column and a mobile phase consists of acetonitrile and water (65:35v/v) adjusted to pH 5.6 with The acetate buffer, flow rate used was (1.1ml/min), the temperature was 27˚C and UV detection at 245nm. The retention time of Aspirin and Rivaroxaban was found to be 2.1min and 3.2min respectively. Developed method was validated according to ICH Q2 (R1) guidelines. The method was found to be linearity (R2>0.999) in the concentration range of (10 – 600) μg/ml for Aspirin and (10-100) μg/ml for Rivaroxaban. The precision (intra-day, inter-day) data of this method was found to be within limits (% RSD < 2%), The mean recoveries obtained for aspirin and Rivaroxaban were (99.60 - 101.10)% respectively, so developed method was found to be accurate.
KEYWORDS: Aspirin, Rivaroxaban, RP-HPLC, Synthetic Mixture, Validation.
1. INTRODUCTION:
Aspirin is 2- (acetyloxy) benzoic acid and is cyclo oxygenase inhibitor which is best known as an antiplatelet drug[1], is white crystalline powder which is weakly acidic, Molecular mass – 180.157 g/mol, molecular formula - C9H8O4 (Figure 1).
Aspirin is one of the major antithrombogenic agent widely used for the treatment and prevention of cerebro and cardiovascular conditions such as stroke[2], Antiplatelet therapy has been documented to reduce risks of cardiovascular disease after acute myocardial infarction, coronary artery bypass graft, and in chronic atrial fibrillation patients, amongst other risk factors.
Conventional management of thrombosis-based disorders includes the use of heparin, oral anticoagulants, and the preferred antiplatelet agent aspirin. Interestingly, aspirin was not intended to be used as an antiplatelet agent; rather, after being repurposed, it has become one of the most widely prescribed antithrombotic drugs[3].
Rivaroxaban (chemical name 5-chloro-N-[[(5S)-2-oxo-3-[4-(3 oxomorpholin-4-yl) phenyl]-1,3-oxazolidin-5 yl]methyl] thiophene-2-carboxamide) is a small-molecule (molecular weight, 436g/mol) only slightly soluble in organic solvents and is practically insoluble in water. molecular formula - C19H18ClN3O5S[4] (Figure 1).
Rivaroxaban is novel, oral, direct factor (F) Xa inhibitor in advanced clinical development for the prevention and treatment of thromboembolic diseases[5], Rivaroxaban is approved in more than 100 countries worldwide, including the European Union and Canada, for the prevention of venous thromboembolism after elective hip or knee replacement surgery in adult patients, and is in advanced clinical development for the treatment of thromboembolic disorders, the prevention of stroke in patients with atrial fibrillation, and the secondary prevention of acute coronary syndromes Rivaroxaban only targets one factor within the coagulation cascade, Factor Xa, and its mechanism of action is antithrombin (AT) independent[6]
Fig. 1. Chemical structures of Aspirin and Rivaroxaban.
The US Food and Drug Administration (FDA) has approved Rivaroxaban in combination with Aspirin to reduce the risk for major cardiovascular (CV) events in adults with chronic coronary artery disease (CAD) or peripheral artery disease (PAD)[7].
"Treating patients with Aspirin only is simply not enough to address the underlying thrombotic risk that comes with chronic CAD and PAD. As we saw in the COMPASS trial, the dual pathway approach of Aspirin and the 2.5mg, twice-daily dose of Rivaroxaban can help significantly reduce the risk of CV events in these populations[7].
Based on literature survey it is found that various analytical methods like UV spectroscopy[8,9], High Performance Thin Liquid Chromatography (HPTLC)[10,11], Reverse Phase High performance Liquid Chromatography (RP–HPLC)[12-16] Liquid Chromatography and Mass Spectroscopy (LC-MS)[17], spectrofluorometric[18], spectrometric method[19] have been reported for the determination and estimation of as Aspirin individual drug and combination with other drug.
It is found that various analytical methods like UV spectroscopy[20,21], Reverse Phase High performance Liquid Chromatography (RP–HPLC)[22-27], Liquid Chromatography and Mass Spectroscopy (LC-MS)[28] have been reported for the determination and estimation of as Rivaroxaban individual drug and combination with other drug.
But, No method was reported for selective estimation of these two drugs in combination. Therefore, it is a thought of interest to develop simple, accurate and precise methods for the simultaneous estimation Aspirin and Rivaroxaban in synthetic mixture. The proposed method was validated according to International Conference on Harmonization (ICH) method validation guidelines[29].
2. MATERIALS AND METHODS:
2-1 Instrumentation:
The HPLC instrument used was an (Agilent 1260 infinity, Germany) equipped with a UV detector, uv/vis spectrometer (PG Instrument Limited, Model T80, UK), pH meter (Crison, Spain), ultrasonic processor (Powersonic, model 405, Korea), analytical balance ±0.1mg (Sartorius, model 2215, Germany).
2-2 Reagents and Chemicals:
Standard API of Aspirin and Rivaroxaban was gifted by (Ibn Al Haytham Pharmaceutical Industries).
All the other used reagents were of HPLC grade: acetonitrile (Chem-Lab N V, Belgium), Acetic acid (Scharlau Chemie. S.A, Spain), Sodium acetate(Hi Media Laboratories Pvt. Ltd, Mumbai -India) deionized water for HPLC and filters 0.45μm.
2-3 Method development and optimization of chromatographic conditions
· Column selection:
C18- reversed phase column, 250 x 4.6mm 5-µm was utilized.
· Preparation of Buffer:
1- Preparation of standard stock solution of Acetic acid (0.2M): (11.55ml in 1000ml).
2- Preparation of standard stock solution of Sodium acetate (0.2M): by dissolving 1.64g of C2H3O2Na in deionized water for HPLC using 100mL volumetric flask to give the final concentration of 0.2M.
An aliquot of stock solution of Acetic acid and stock solution of Sodium acetate (4.8ml+45.2ml) in 100ml volumetric flask and further diluted with deionized water for HPLC to attain Required acetate buffer[30].
· Preparation of mobile phase:
The mobile phase consisting of acetonitrile and water (65:35v/v) adjusted to pH (5.6) with The acetate buffer, flow rate used was (1.1ml/min).
· Preparation of standard solutions:
1- Stock solution of Aspirin:
Preparation of standard stock solution of Aspirin (1000 μg/ml): Accurately weight 100mg of Aspirin was transferred into a 100ml volumetric flask and diluted with acetonitrile: acetate buffer pH (5.6) (80/20v/v)
2- Stock solution of Rivaroxaban:
Preparation of standard stock solution of Rivaroxaban (100μg/ml): Accurately weight 100mg of Rivaroxaban was transferred into a 100ml volumetric flask and diluted with acetonitrile and acetate buffer pH (5.6) (80:20v/v). From above 10ml was pipetted out in 100ml volumetric flask and made up to the mark with acetonitrile and acetate buffer pH (5.6) (80:20v/v) to make final concentration of Rivaroxaban 100μg/ml.
· Preparation of synthetic mixture of Aspirin and Rivaroxaban:
The synthetic mixture of Aspirin and Rivaroxaban was prepared in the ratio 20:1.
Powder weight equivalent to 2.5mg of Rivaroxaban and 50mg of Aspirin was taken and then added other excipients 4mg Povidone, 15mg Micro crystalline cellulose, 2mg Magnesium- Stearate, 1mg Talc and 88 mg dilute Lactose Monohydrate into Petri dish. Then, transferred into 100ml volumetric flask. Added 50ml of Acetonitrile and sonicated it. Diluted up to the mark with acetonitrile: acetate buffer pH (5.6) (80:20v/v). This solution was filtered through Whatman Filter paper. The mixture contains 25μg/ml of Rivaroxaban and 500μg/ml of Aspirin.
From above synthetic mixture, 8 ml was pipetted out in 10ml volumetric flask and made up to the mark with mobile phase to make final concentration of Rivaroxaban 20μg/ml and Aspirin 400μg/ml.
· Selection of wavelength:
An appropriate aliquot portion of Aspirin (4mL) and Rivaroxaban (2mL) were transferred to two separate 10 mL volumetric flasks, the volume was made up to the mark using acetonitrile-water (80/20v/v) to obtain Aspirin (400µg/mL) and Rivaroxaban (20µg/mL). Drug solutions were scanned separately between 200nm to 400nm. Aspirin shows λ max at 212nm while Rivaroxaban at 249nm, 245nm was selected for detection of Rivaroxaban and Aspirin (Figure 2).
RIVAROXABAN
Fig 2: Overlain Spectra of Aspirin
and Rivaroxaban
Tab. 1. Optimized chromatographic conditions of the developed method:
|
Column |
C18- reversed phase column, 250 x 4.6 mm 5-µm |
|
Temperature |
27° C |
|
Flow rate |
1.1 ml/min |
|
Mobile phase |
Acetonitrile: Water (65:35v/v) adjusted to pH (5.6) with The acetate buffer |
|
Detector |
UV detector |
|
injection volume |
20 µl |
|
maxλ |
245 nm |
3. ANALYTICAL METHOD VALIDATION:
Method validation was performed in according to International Conference on Harmonization (ICH) recommended test conditions[29].
4. RESULT AND DISCUSSION:
HPLC analysis:
The chromatographic conditions comprised of a C18 reversed phase column, 250 x 4.6mm 5-µm, with a mobile phase consisting of acetonitrile: water (65:35v/v) adjusted to pH (5.6) with The acetate buffer, flow rate used was (1.1ml/min), the temperature was 27ºC and UV detection at (245nm). The developed chromatographic method conditions are presented in (Table 1).
The reference solutions of Aspirin, Rivaroxaban and synthetic mixture were injected under the previous chromatographic conditions, the retention time for Aspirin was 2.1 min, and 3.2 min for Rivaroxaban (Fig.3,4).
Fig 3: A. Chromatogram of Aspirin (400μg/ml) B. Chromatogram of Rivaroxaban (20μg/ml)
Fig 4: Chromatogram of Synthetic Mixture Aspirin and Rivaroxaban (400 μg/ml/20 μg/ml)
Analytical method validation:
Linearity:
The linearity of analytical procedure is its ability (within a given range) to obtain test results which are directly proportional to the concentration of an analyte in the sample[29].
The linearity was evaluated by linear regression analysis, which was calculated by the least square regression method.
Calibration curve for aspirin and Rivaroxaban:
For Aspirin:
An aliquots of stock solution of Aspirin (1, 2, 3, 4, 5 and 6ml) were pipetted out from 1000μg/ml stock solution in five different 10ml volumetric flasks and further diluted with mobile phase to attain concentration of 100, 200, 300, 400, 500, 600μg/ml respectively.
Graph of peak Area Vs Concentration was plotted (Fig.5), (Table 2).
For Rivaroxaban:
An aliquots of stock solution of Rivaroxaban (1, 2, 3, 4, 5, 7.5 and 10ml) were pipetted out from 100μg/ml stock solution in five different 10 ml volumetric flasks and further diluted with mobile phase to attain concentration of 10, 20, 30, 40, 50, 75, 100μg/ml respectively.
Graph of peak Area Vs Concentration was plotted (Fig.5), (Table 2).
Fig 5: A. Calibration curve for aspirin (100-600 μg/ml) B. Calibration curve for Rivaroxaban (10-100 μg/ml)
Tab. 2. linearity study data (Aspirin & Rivaroxaban)
|
Aspirin |
Rivaroxaban |
||||
|
Theoretical Conc. (μg/ml) |
Found Conc. (μg/ml) ± SD (n=3) |
RSD% |
Theoretical Conc. (μg/ml) |
Found Conc. (μg/ml) ± SD (n=3) |
RSD% |
|
100 |
101.0723±0.2247 |
0.22 |
10 |
10.1951±0.0659 |
0.65 |
|
200 |
198.9543±0.0897 |
0.05 |
20 |
20.1889±0.0828 |
0.41 |
|
300 |
303.7741±0.0893 |
0.03 |
30 |
30.0752±0.0176 |
0.06 |
|
400 |
398.9458±1.2165 |
0.30 |
40 |
40.0642±0.0324 |
0.08 |
|
500 |
489.5846±1.2210 |
0.24 |
50 |
49.6023±0.0363 |
0.07 |
|
600 |
607.6531±0.9617 |
0.16 |
75 |
74.1275±0.1543 |
0.21 |
|
|
|
|
100 |
100.7495±0.1469 |
0.15 |
Range:
linearity was conformed in the interval (100-600)μg/ml for aspirin and interval (10-100)μg/ml for Rivaroxaban.
Specificity:
Specificity is the ability to assess unequivocally the analyze in the presence of components which may be expected to be present. Typically, these might include impurities, matrix etc.
A solution of placebo in mobile phase and Mobile phase were injected and the chromatogram showed no inferring peaks at retention time of the two drugs. Further Aspirin and Rivaroxaban individually were injected which confirm that Aspirin was eluted at 2.1 min and Rivaroxaban was eluted at 3.2 min.
Precision:
Repeatability precision was established by injecting six replicate injections of standard solution (400μg/ml) Aspirin, and (20μg/ml) Rivaroxaban, the results are shown in (Table 3).
The precision of a method is defined as the closeness of agreement between independent test results obtained under optimum conditions.
Three different concentrations of Aspirin and Rivaroxaban in the linear range were analyzed in 3 independent series in the same day (intra-day precision) and 3 consecutive days (inter-day precision). The precision of the analysis was determined by calculating the relative standard deviation (RSD %), and it was less than 2% for both Aspirin and Rivaroxaban (Table 4).
Tab. 3. Repeatability precision of Aspirin and Rivaroxaban by proposed methods:
|
Aspirin 400 μg/ml |
Rivaroxaban 20 μg/ml |
||||
|
Injection no. |
Area counts |
Found Conc(μg/ml) |
Injection no. |
Area counts |
Found Conc(μg/ml) |
|
1 |
1895.162 |
400.303 |
1 |
585.482 |
20.597 |
|
2 |
1883.819 |
397.954 |
2 |
571.542 |
20.109 |
|
3 |
1886.838 |
398.580 |
3 |
578.549 |
20.354 |
|
4 |
1879.721 |
397.106 |
4 |
581.244 |
20.449 |
|
5 |
1877.833 |
396.715 |
5 |
576.272 |
20.275 |
|
6 |
1880.211 |
397.207 |
6 |
573.591 |
20.181 |
|
Mean |
1883.930 |
397.978 |
Mean |
577.780 |
20.327 |
|
SD |
6.377 |
1.320 |
SD |
5.111 |
0.178 |
|
RSD% |
0.34 |
0.33 |
RSD% |
0.88 |
0.88 |
Sensitivity:
Limit of Detection (LOD) and Limit of Quantification (LOQ) were calculated to evaluate the sensitivity of the proposed methods. The calculated LOD and LOQ for Aspirin were 18.31μg/ml and 55.47μg/ml, respectively, The calculated LOD and LOQ for Rivaroxaban were 1.69μg/ml and 5.11μg/ml.
Accuracy:
To determine the accuracy of the proposed method, recovery studies were carried out. Different amounts (50%, 100%, and 150%) from standard of Aspirin and Rivaroxaban within the range of linearity.
Tab. 4. Intermediate precision of Aspirin by proposed methods:
|
Aspirin |
Intraday Precision |
Interday Precision |
||
|
Theoretical Conc. (μg/ml) |
Found Conc. (μg/ml) ± SD (n=3) |
RSD% |
Found Conc. (μg/ml) ± SD (n=3) |
RSD% |
|
200 |
202.2973±0.3727 |
0.18 |
203.2545±1.2835 |
0.63 |
|
400 |
401.2752±1.0450 |
0.26 |
404.9422±4.1231 |
1.02 |
|
500 |
493.1921±1.5861 |
0.32 |
497.3519±4.7253 |
0.95 |
|
Rivaroxaban |
Intraday Precision |
Interday Precision |
||
|
Theoretical Conc. (μg/ml) |
Found Conc. (μg/ml) ± SD (n=3) |
RSD% |
Found Conc. (μg/ml) ± SD (n=3) |
RSD% |
|
10 |
9.8891±0.0603 |
0.61 |
9.8952±0.0469 |
0.47 |
|
30 |
30.0896±0.1861 |
0.69 |
30.1029±0.1661 |
0.55 |
|
75 |
74.1981±0.0599 |
0.08 |
74.1728±0.0648 |
0.09 |
Tab. 5. Accuracy study data:
|
Aspirin |
|||||||
|
Level of Recovery % |
Test Amt. (μg/ml) |
Amount of Drug Spiked (μg/ml) |
Total Amt. Recovered (μg/ml) |
Recovery % |
Recovery Mean % |
SD |
RSD% |
|
50% |
400 |
200 |
201.9370 |
100.9685 |
100.7732 |
0.3880 |
0.39 |
|
400 |
200 |
200.6527 |
100.3263 |
||||
|
400 |
200 |
202.0501 |
101.0250 |
||||
|
100% |
400 |
400 |
398.4970 |
99.6242 |
99.6026 |
0.2047 |
0.21 |
|
400 |
400 |
397.5515 |
99.3878 |
||||
|
400 |
400 |
399.1828 |
99.7957 |
||||
|
150% |
400 |
600 |
607.4784 |
101.2464 |
101.0980 |
0.1377 |
0.14 |
|
400 |
600 |
605.8445 |
100.9740 |
||||
|
400 |
600 |
606.4413 |
101.0735 |
||||
|
|
overall |
100.4913 |
0.7865 |
0.78 |
|||
|
Rivaroxaban |
|||||||
|
Level of Recovery % |
Test Amt. (μg/ml) |
Amount of Drug Spiked (μg/ml) |
Total Amt. Recovered (μg/ml) |
Recovery % |
Recovery Mean % |
SD |
RSD% |
|
50% |
50 |
25 |
25.1366 |
100.5465 |
100.8270 |
0.2689 |
0.27 |
|
50 |
25 |
25.2129 |
100.8519 |
||||
|
50 |
25 |
25.2706 |
101.0826 |
||||
|
100% |
50 |
50 |
49.5348 |
99.0697 |
99.2750 |
0.2111 |
0.21 |
|
50 |
50 |
49.6319 |
99.2638 |
||||
|
50 |
50 |
49.7457 |
99.4915 |
||||
|
150% |
50 |
75 |
74.2046 |
98.9395 |
98.9952 |
0.0642 |
0.06 |
|
50 |
75 |
74.2353 |
98.9804 |
||||
|
50 |
75 |
74.2991 |
99.0655 |
||||
|
|
overall |
99.6990 |
0.9867 |
0.99 |
|||
Recovery results for Aspirin (99.60 - 101.10)%, and for Rivaroxaban (98.99 - 100.8270)% were among the accepted range of accuracy (98-102%) which indicates that developed method is accurate and applicable to the determination of Aspirin and Rivaroxaban (Table 5).
Application To Synthetic Mixture:
Applicability of proposed method was tested by analysing the synthetic mixture of Aspirin and Rivaroxaban. (Table 6).
Tab. 6. Applicability to the synthetic mixture of Aspirin and Rivaroxaban:
|
Drug |
Amount Theoretical (mg) |
Amount found (mg) (n=3) ± SD |
Recovery % |
|
Aspirin |
50 |
49.8038 ± 0.5403 |
99.61 |
|
Rivaroxaban |
2.5 |
2.5319 ± 0.0442 |
101.28 |
5. CONCLUSION:
Simple, rapid, accurate and precise RP-HPLC method was developed and validated for simultaneous estimation of Aspirin and Rivaroxaban in synthetic mixture.
The developed method is suitable for the identification and quantification of binary combination of aspirin and Rivaroxaban in bulk and finish formulation.
The analytical conditions and the solvent system developed provided a high percentage of recovery and short run time (less than five minutes).
Thus, the developed HPLC method can be utilized for the routine analysis and quality control of pharmaceutical preparations containing Aspirin and Rivaroxaban either individually or in combination.
6. REFERENCES:
1. Patel GF, Vekariya NR, Dholakiya, RB. Estimation of Aspirin and Atorvastatin Calcium in Combine Dosage Form Using Derivative Spectrophotometric Method. Int. J. Pharm. Res. 2010; 2(1): 62-66.
2. Purushotam KS, Mrinalini CD, Bothara KG. A Validated Stability Indicating HPTLC Method for Determination of Aspirin and Clopidogrel Bisulphate in Combined Dosage Form. Eur. J Anal. Chem. 2009; 4(2): 152-160.
3. Paez-Espinosa E, Murad J, Khasawneh F. Aspirin: Pharmacology and Clinical Applications. Hindawi Publishing Corporation Thrombosis, 2012; (15).
4. European Medicines Agency (EMEA). CHMP Assessment Report for Xarelto. Available at: http://www.emea.europa.eu/humandocs/PDFs/EPAR/ xarelto/H-944-en6.pdf. 2008. Accessed January 14, 2010.
5. Perzborn E, Strassburger J, Wilmen A. In vitro and in vivo studies of the novel antithrombotic agent BAY 59–7939 an oral, direct factor Xa inhibitor. J Thromb Haemost. 2005; 3: 514–521.
6. Kubitza D, Becka M, Voith B, Zuehlsdorf M, Wensing G. Safety, pharmacodynamics, and pharmacokinetics of single doses of BAY 59 7939, an oral, direct factor Xa inhibitor. Clin Pharmacol Ther. 2005; 78: 412–421.
7. U.S. FDA Approves XARELTO® (rivaroxaban) to Reduce the Risk of Major Cardiovascular Events in Patients with Chronic Coronary Artery Disease (CAD) or Peripheral Artery Disease (PAD) [news release]. Titusville, NJ; October 11, 2018: Janssen Pharmaceuticals website. https://www.janssen.com/us-fda-approves-xareltor-rivaroxaban-reduce-risk-major-cardiovascular-events-patients-chronic. Accessed October 12, 2018.
8. Kokot Z, Burda K. Simultaneous determination of salicylic acid and acetylsalicylic acid in aspirin delayed release tablets formulation by second-derivative UV Spectrophotometry. J. Pharma. Bio. 1998; 18: 871-875.
9. Murtaza G, Khan SA, Shabbir A, Mahmood A, Asad MHHB, Farzana K, Malik NS, Hussain I. Development of a UV spectrophotometric method for the simultaneous determination of aspirin and paracetamol in tablets. Sci. Res. Ess. 2011; 6: 417-421.
10. Panchal HJ, Suhagia BN, Patel NJ. Simultaneous HPTLC analysis of atorvastatin calcium, ramipril and aspirin in capsule dosage form. J. Planar Chromatogr. 2009; 22: 265-271.
11. Sinha PK, Damle MC, Bothra KG. A validated stability indicating HPTLC method for the determination of aspirin and clopidrogrel bisulphate in combined dosage form. Eur. J. Anal. Chem. 2009; 4: 152-160.
12. Jain D K, Jain N, Verma J. RP-HPLC Method for Simultaneous Estimation of Aspirin and Prasugrel in Binary Combination International. Journal of Pharmaceutical Sciences and Drug Research. 2012; 4(3): 218-221.
13. Panchal A, Sanghvi G, Vachhani A, Sheth N, Vaishnav D. Simultaneous determination of Aspirin and Rosuvastatin Calcium in capsules by using RPHPLC coupled with photo diode array detection. International Letters of Chemistry, Physics and Astronomy. 2014; 33: 218-230.
14. Chodvadiya FJ, Thula KC, Maheshwari DG. Simultaneous estimation of aspirin and lansoprazole by RP–HPLC method. International Journal of Recent Scientific Research. 2015; 6(4): 3385-3390
15. Gandimati M, Ravi TK, Abraham A, Thomas R. Simultaneous determination of aspirin and isosorbide 5-mononitrate in formulation by RP-HPLC. J. Pharm. Biomed. 2003; 32: 1145-1148.
16. Pirola R, Bareggi SR, Benedittis GD. Determination of acetylsalicylic acid and salicylic acid in skin and plasma by high performance liquid chromatography. J. Chromatogr B. 1998; 705: 309-315.
17. Tsikasa D, Tewesa KS, Gutzkia FM, Schwedhelma E, Greipel J, Frolich JC. Gas chromatographic-tandem mass spectrometric determination of acetylsalicylic acid in human plasma after oral administration of low-dose aspirin and guaimesal. J. Chromatogr B. 1998; 709: 79-88.
18. Umapathi P, Parimoo P, Thomas SK, Agarwal V. Spectrofluorometric estimation of aspirin and dipyridamole in pure admixtures and in dosage forms. J. Pharm. Biomed. 1997; 15: 1703-1708.
19. Ahmed M, Biswas HU, Sadik G. Development of a spectrometric method for the determination of aspirin in blood samples. J. Med. Sci. 2001; 2:61-62.
20. Sekaran CB, Bind VH, Damayanthi MR, Sireesha A. Development and validation of UV spectrophotometric method for the determination of rivaroxaban. Der Pharma Chemica. 2013; 5(4): 1-5.
21. Celebier M, Kaynak MS, Altınoz S, Sahin S. UV Spectrophotometric Method for Determination of the Dissolution Profile of Rivaroxaban. Dissolution Technologies. 2014; 56-59.
22. Mehta AR, Maheshwari DG. Development and validation of first uv spectrophotometric method and RP-HPLC method for simultaneous estimation of rivaroxaban and ticagrelor in synthetic mixture. Journal of Global Trends in Pharmaceutical Sciences. 2018; 9(2): 5275 – 5297.
23. Celebier M, Recber T, Kocak E, Altınoz S. RP-HPLC method development and validation for estimation of rivaroxaban in pharmaceutical dosage forms. Brazilian Journal of Pharmaceutical Sciences. 2013; 49(2): 360-366.
24. Sunny A, Sreedhar C, Akkama HG, Mahapatra A. (2017). Development of New Analytical Method and Vallidation For Quantitative Estimation of Rivaroxaban in Formulation and Bulk Drug. International Journal of Scientific Research in Education. 2017; 5(5): 6469-6478.
25. Sahoo S, Mekap SK. Assay comparison of rivaroxaban by new HPLC method with an existing method in tablet dosage form. Pharmaceutical and Biological Evaluations. 2017; 4(3): 180-182.
26. Avachat AM, Yamgar MP. RP-HPLC method development and validation for the estimation of rivaroxaban in bulk and tablet dosage form. World Journal of Pharmacy and Pharmaceutical sciences. 2017; 6(8): 1775-1784.
27. Seshamamba B, Satyanarayana P, Sekaran C. Application of Stability Indicating HPLC Method with UV Detector to the Analysis of Rivaroxaban in Bulk and Tablet Dosage Form. Chemical Science Transactions. 2014; 3(4): 1546-1554.
28. Arous B, Al-Mardini MA, Ghazal H, Al-Lahham F. Stability-Indicating, Method, for the Determination, of Rivaroxaban, and its Degradation, Products, using, LC-MS, and, TLC. Research J. Pharm. and Tech. 2018; 11(1): 8.
29. ICH Q2(R1). Validation of Analytical
Procedures: Text and Methodology. International Conference on Harmonisation of Technical
Requirements for Registration of Pharmaceuticals for Human Use. 2005
30. Stoll VS, Blanchard JS. Buffers: Principles and Practice. Academic Press, 1990; 463(6).
Received on 11.11.2019 Modified on 04.02.2020
Accepted on 27.03.2020 © RJPT All right reserved
Research J. Pharm. and Tech. 2020; 13(11):5459-5465.
DOI: 10.5958/0974-360X.2020.00953.1